![]() Not all scanners withĭocument feeders signal when the ADF is empty, use this command to work around them. If not given, scanimage will continue scanning until the scanner returns a state other than OK. If this option is not given, the counter will start at 0. Selects the page number to start naming files with. format is given as a printf style string with one integer parameter. Out%d.tif for -format tiff) will be used. If format is not specified, the default of out%d.pnm (or Each page is written out to a single file. Of the filename that each page will be written to. The -batch* options provide the features for scanning documents using document feeders. Scanner number 0 device sharp:/dev/sg1 is a flatbed scanner, model JX250 SCSI, produced by SHARP Scanimage -f " scanner number %i device %d is a %t, model %m, produced by %v " will produce something like: Placeholders %d %v %m %t %i %n with the device name, vendor name, model name, scanner type, an index number and newline respectively. The -f or -formatted-device-list option works similar to -list-devices, but requires a format string. Need to consult your system administrator to find out the names of such devices. If a device is not listed in a configuration file, the only way to access it is by its full device name. When accessing scanners through the network. The list is not complete since some devices may beĪvailable, but are not listed in any of the configuration files (which are typically stored in directory /etc/sane.d). The -L or -list-devices option requests a (partial) list of devices that are available. The -i or -icc-profile option is used to include an ICC profile into a TIFF file. The -format format option selects how image data is written to standard output. If this variable is not set, scanimage will attempt to Scanimage reads a device-name from the environment variable SANE_DEFAULT_DEVICE. If no device-name is specified explicitly, (partial) list of available devices can be obtained with the -list-devices option (see below). The -d or -device-name options must be followed by a SANE device-name like ' epson:/dev/sg0' or ' hp:/dev/usbscanner0'. d epson) and by a "=" from multi-character options (e.g. Parameters are separated by a blank from single-character options (e.g. Scanimage -x 100 -y 100 -format=tiff >image.tiff To scan 100x100 mm to the file image.tiff (-x and -y may not be available with all devices): To scan with default settings to the file image.pnm: scanimage accesses image acquisition devices through the SANE (Scanner Access Now Easy) interface and can thus support anyĭevice for which there exists a SANE backend (try apropos sane- to get a list of available backends). ![]() One of the PNM (portable aNyMaP) formats (PBM for black-and-white images, PGM for grayscale images, and PPM for color images) or in TIFF (black-and-white, The image data is written to standard output in After command-line processing, scanimage normally proceeds to acquire an image. ![]() The device is controlled viaĬommand-line options. Scanimage is a command-line interface to control image acquisition devices such as flatbed scanners or cameras. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |